Yaskawa VS-626 MC5 User Manual

Page 133

Advertising
background image

Basic Operation

6.3.4 Autotuning for machine tool spindle motors

- 30

J

Constant setting prior to autotuning

Following constants must be set before performing autotuning.

D

Motor leak inductance (E2-06)

Set motor leak inductance using the following formula.

Setting by the motor leak inductance L (= L1 + L2)

(

E2

06

)

3

¯ 

2

 Q  Rated frequency at base speed (

Hz

)



L

(

H

)

 Rated current at base speed (

A

)

No–load voltage at base speed (

V

)



100

(

%

)

Note : Refer to Fig.6.11 for details of leakage inductance “L”.

Setting by the lock test values

(E2–06)

3

¯  (Vs

2

3Is

2

)

 (Ps3Is

2

)

2

¯

 Rated current at base speed (A)

No–load voltage at base speed (V)

 100(%)

Vs Lock test voltage V
Is

Lock test current A

Ps Lock test loss W

The result of the above formula should be from 5 to 25%. Verify the data when the obtained results are
too large (or small).

D

Carrier frequency

Set carrier frequency to 5.0 kHz.
Carrier frequency during autotuning: C8-30=1 (Carrier frequency is set to a value as set in C6-01)
Carrier frequency upper limit: C6-01=5.0 kHz

J

Required Constant Settings

1.

Enter autotuning mode and make the following constant settings:

x

Rated Voltage

Set the rated voltage (VAC) at the base speed(r/min).

x

Rated Current
Set the rated current (A) at the base speed(r/min).

x

Rated Frequency
Set the rated frequency (Hz) at the base speed.

x

Rated Speed(r/min)
Set the rated speed (r/min) at the base speed.

x

Number of Poles
Set the number of poles.

x

Motor Selection
Select motor 1 or 2.

x

Number of PG pulse
Set the number PG pulse.

2.

The following message will appear when the constants have been set:

Tuning Ready?

Press RUN Key

The “Press RUN Key” message will
blink.

3.

At this point, it is still possible to change the constant settings by pressing the
Increment ( ) and Decrement ( ) Keys to display the desired constant.

4.

Press the STOP Key to cancel autotuning, and then press the MENU Key and DATA/ENTER Key.
The operation mode display will appear.

J

Performing Autotuning

D

Autotuning will start if the Run Key is pressed when the “Tuning Ready?” message is being displayed.

D

The motor will operate during autotuning, so be sure that it is safe for the motor to operate before press-
ing the RUN Key.

D

The following message will be displayed when the Run Key is pressed:

Tune Proceeding

Hz

A

The “Tune Proceeding” message will blink.

D

Autotuning takes up to 1.5 minutes. The message “Tune Successful” will be displayed when autotun-
ing is completed.

D

When autotuning has been completed successfully, record the motor constants. Repeat autotuning for
three times and set to the resulting average (value).

6

Advertising