6.1

Common Settings

- 13

J

3-wire Sequence (Forward/Reverse Run Commands): “0”

D

When a value of “0” is set for any one of the multi-function inputs (H1-01 through H1-06), 3-wire se-
quence control is used and the multi-function input terminal for which “0” was set becomes the for-
ward/reverse run command terminal.

D

When the Unit is initialized for 3-wire sequence control with A1-03 , multi-function input 3 (terminal
5) becomes the input terminal for the forward/reverse run command.

Stop switch (NC) Run switch (NO)

Run command
(Operates when the run switch is closed.)

1

2

Stop command
(Stops when the stop switch is open.)

Forward/reverse command
(Multi-function input)

11

Sequential input common

5

Fig

6.5

3-wire Sequence Wiring Example

50 ms min.

Run command

Stop command

Forward/reverse run
command

Motor speed

ON/OFF (Either is possible.)

OFF (Stop)

OFF (Forward)

ON (Reverse)

Stop

Forward

Reverse

Stop

Forward

Fig

6.6

Timing Chart for 3-wire Sequence

J

Multi-step Speed References 1 through 3 and JOG Reference: “3” to “6”

D

Eight frequency references and one jog frequency reference can be used.

D

Set the multi-step speed references 1, 2, and 3 and the JOG reference for the multi-function inputs, and
change the status of these inputs to switch between the 9 frequency references.

Terminal

Constant

Setting

Function

5

H1-03

3

Multi-step speed reference 1 (Also used for master-speed/auxiliary-speed
switching when an auxiliary reference is set for the multi-function analog
input in H3-05.)

6

H1-04

4

Multi-step speed reference 2

7

HI-05

5

Multi-step speed reference 3

8

H1-06

6

JOG reference (This setting has higher priority than the multi-step speed
reference.)

6