Yaskawa VS-626 MC5 User Manual

Page 122

Advertising
background image

6.2

Open-loop Vector Control

- 19

J

Acquisition of Motor Data

When autotuning motors for machine tool spindles, it is necessary to check the following data for the wind-
ing motors (Y-and - windings).

D

No-load voltage at base speed

D

Rated current at base speed

D

No-load frequency at base speed

D

Base speed(r/min)

D

Number of poles

D

No-load frequency at max. speed

D

No-load voltage at max. speed

D

Rated voltage (with 100% load)

D

Leakage inductance (L = L1 + L2)
Refer to Fig. 6.8 for details.

L1

R1

R2/s

L2

Rm

Lm

R1

Primary resistance

R2

Secondary resistance

S

Slip

Rm Iron loss resistance
Lm

excitation inductance

Fig

6.8

Motor equivalent circuit (One phase, Example of Y-winding)

J

Constant setting prior to autotuning

Following constants must be set before performing autotuning.

D

Motor leak inductance (E2-06)

Set motor leak inductance using the following formula.

Setting by the motor leak inductance L (= L1 + L2)

(

E2

06

)

3

¯ 

2

 Q  Rated frequency at base speed (

Hz

)

 L (

H

)

 Rated current at base speed (

A

)

No–load voltage at base speed(

V

)



100

(

%

)

Note:Refer to Fig. 6.8 for details of leakage inductance

L”.

Setting by the lock test values

(E2–06)

3

¯  (Vs

2

3Is

2

)

 (Ps3Is

2

)

2

¯

 Rated current at base speed (A)

No–load voltage at base speed (V)

 100(%)

Vs Lock test voltage V
Is

Lock test current A

Ps Lock test loss W

The result of the above formula should be from 5 to 25%. Verify the data when the obtained results are
too large (or small).

D

Carrier frequency

Set carrier frequency to 5.0 kHz.
Carrier frequency during autotuning: C8-30=1 (Carrier frequency is set to a value as set in C6-01)
Carrier frequency upper limit: C6-01=5.0 kHz