Yaskawa VS-626 MC5 User Manual

Page 199

Advertising
background image

7.3

Common Functions

- 61

User

Change

during

Setting

Factory

Valid Access Levels

User

Constant

Number

Name

during

Opera-

tion

Setting

Range

Unit

Factory

Setting

Open Loop

Vector

Flux Vector

o1-04

Frequency units of
constant setting

0 1

--

0

B

D

Settings

Setting

Unit

0

Unit of setting: Hz

1

Unit of setting: r/min

Constant Number Display Selection: o1-05

User

Change

during

Setting

Factory

Valid Access Levels

User

Constant

Number

Name

during

Opera-

tion

Setting

Range

Unit

Factory

Setting

Open Loop

Vector

Flux Vector

o1-05

Constant No. display
selection

0 1

--

0

A

A

D

Settings

Setting

Function

0

Display constant number

1

Display constant number (address) set for MEMOBUS communications

J

Key Function Settings/Other Settings: o2-01 to o2-08

LOCAL/REMOTE Key Enable/Disable: o2-01

User

Change

during

Setting

Factory

Valid Access Levels

User

Constant

Number

Name

during

Opera-

tion

Setting

Range

Unit

Factory

Setting

Open Loop

Vector

Flux Vector

o2-01

LOCAL/REMOTE key
enable/disable

0 1

--

1

B

B

D

This constant enables or disables the LOCAL/REMOTE Key (the Operation Mode Selector Key) on
the Digital Operator.

D

Settings

Setting

Function

0

Disabled. (Cannot change between local and remote.)

1

Enabled. (Pressing the LOCAL/REMOTE Key switches control of operation between the Oper-
ator and the sources specified in constants b1-01 and b1-02.)

STOP Key During Control Circuit Terminal Operation: o2-02

User

Change

during

Setting

Factory

Valid Access Levels

User

Constant

Number

Name

during

Opera-

tion

Setting

Range

Unit

Factory

Setting

Open Loop

Vector

Flux Vector

o2-02

STOP Key during con-
trol circuit terminal op-
eration

0 1

--

1

B

B

D

This constant enables or disables the STOP on the Digital Operator

D

Settings

Setting

Function

0

Disabled. (The STOP Key is disabled when the run command is input from an external termi-
nal.)

1

Enabled. (The STOP Key is enabled at all times during operation.)

User Constant Initial Value: o2-03

User

Change

during

Setting

Factory

Valid Access Levels

User

Constant

Number

Name

during

Opera-

tion

Setting

Range

Unit

Factory

Setting

Open Loop

Vector

Flux Vector

o2-03

User constant initial val-
ue

0 to 2

--

0

B

B

D

This constant is used to record or clear the user constant defaults.

7