Advanced Operation

7.2.2 Setting/Adjusting Motor Constants

- 12

D

Settings

Setting

Name

10

Forward Torque Limit

11

Reverse Torque Limit

12

Regenerative Torque Limit

13

Torque reference (The input limits torque in both the forward and reverse directions during
speed control.)

15

Forward/Reverse Torque Limit (Limits torque in both the forward and reverse directions.)

D

The above table shows only those settings related to the torque limit function.

D

Set the analog input terminal’s signal level, gain, and bias to match the actual input signal.

D

The factory default settings for the input terminal’s signal level are as follows:

x

Terminal 16: 0 to +10 V (A 10 V input limits the torque to 100% of the motor’s rated torque.)

x

Terminal 14: 4 to 20 mA (A 20 mA input limits the torque to 100% of the motor’s rated torque.)

Figure 7.6 shows the relationship between the output torque and each torque limit.

Output torque

Forward
direction

Reverse
direction

Regenerative torque limit

Reverse torque limit

Motor speed

Reverse

Forward

Forward torque limit

Regenerative torque limit

Fig

7.6

Limiting Torque via Analog Inputs

D

When the forward torque limit has been set, the analog input signal acts as the limit value for torque
generated in the forward direction. The torque limit input is effective when torque is generated in the
forward direction even if the motor is operating in reverse (regenerative torque).

D

The torque limit is 100% of the motor’s rated torque when the analog input is at its maximum value
(10 V or 20 mA). To increase the torque limit above 100%, set the input terminal’s gain above 100%.
For example, a gain of 150.0% would result in a torque limit of 150% of the motor’s rated torque with
a 10 V or 20 mA analog input.

7.2.2 Setting/Adjusting Motor Constants

J

Adjusting the V/f Pattern: E1-04 to E1-06, E1--09, E1-13

D

Normally it isn’t necessary to adjust the V/f pattern with flux vector control. Adjust the V/f pattern
when you want to change the maximum output frequency, maximum voltage, base frequency, or mini-
mum output frequency settings.

User

Change

during

Setting

Factory

Valid Access Levels

User

Constant

Number

Name

during

Opera-

tion

Setting

Range

Unit

Factory

Setting

Open Loop

Vector

Flux Vector

E1-04

Max. output frequency

40.0 to

400.0

Hz

60.0

Q

Q

E1-05

Max. voltage

0.0

to

255.0

*1

VAC

200.0

*1

Q

Q

E1-06

Base frequency

0.0 to 400.0

Hz

60.0

Q

Q

E1-09

Min. output frequency

0.0 to 400.0

Hz

0.0

Q

A

E1-13

Base voltage

0.0 to 255.0

VAC

0.0

*2

Q

Q

* 1. These voltages are for the 200 V class; Double the voltage for 400 V class Inverters.
* 2. If E1-13 is set to 0.0, the same value as in E1-13 will be set for E1-05. It does not normally

need to be set separately.

Note 1.The default setting for E1-09 depends on the control method. The default settings shown

in the table are for flux vector control.

2. The three frequency settings must satisfy the following equation:

E1-04 (F

MAX

)

t E1-06 (F

A

) > E1-09 (F

MIN

)

7