Yaskawa VS-626 MC5 User Manual

Page 82

Advertising
background image

4.2Modes

- 19

J

Selecting the Display Language: A1-00

D

Use constant A1-00 to select the language displayed by the Inverter. A value of 0 sets English and a
value of 1 sets Japanese.

D

This user constant is not returned to the factory setting when constants are initialized. It must be manu-
ally reset to the factory setting.

User

Change

during

Setting

Factory

Valid Access Levels

User

Constant

Number

Name

during

Opera-

tion

Setting

Range

Unit

Factory

Setting

Open Loop

Vector

Flux Vector

A1-00

Language selection for
Digital Operator display

0 (English),

1 (Japanese)

--

1

(Japanese)

Q

Q

Changing the Language to English

Use the following procedure to change the display language from Japanese to English.

Step

Key Sequence

Digital Operator Display

Remarks

1

MENU

MC5

2

MC5

3

DATA

ENTER

(Language)

(Japanese)

4

DATA

ENTER

A1--00 = 1

(Japanese)

Changed to constant setting level.

5

A1--00 = 0

English

6

DATA

ENTER

Entry Accepted

Writes-in the new setting.

Select Language

English

After a few seconds, the Operator dis-
play is as shown on the left.

The display language has been set to English.

J

Setting the Access Level: A1-01

D

Use constant A1-01 to select the user constant access level. This level determines which user constants
can be changed and displayed.

D

The user constants that can be displayed and changed also depend upon the control method being used.

User

Change

during

Setting

Factory

Valid Access Levels

User

Constant

Number

Name

during

Opera-

tion

Setting

Range

Unit

Factory

Setting

Open Loop

Vector

Flux Vector

A1-01

Constant access level

0 4

--

2 Q

Q

Q

Access Level Settings

Setting

Function

0

Operation Only

This setting allows the operation mode and initialize mode to be changed or
displayed.
Use this setting to prevent user constant settings from being changed.

1

User Program

This setting allows only the user-selected constants (up to 32) to be changed
or displayed.
Select the desired user constants in A2-01 through A2-32.

2

Quick-start

This setting allows the user constants required to start the Inverter (about 25)
to be changed or displayed.

3

Basic

This setting allows the commonly used user constants to be changed or dis-
played.

4

Advanced

This setting allows all user constants to be changed or displayed.

4

A

EXAMPLE

"