Yaskawa VS-626 MC5 User Manual

Page 258

Advertising
background image

Troubleshooting

9.2.15 If Output Frequency Does Not Rise to Frequency Reference

- 14

9.2.15 If Output Frequency Does Not Rise to Frequency Reference

J

The frequency reference is within the jump frequency range.

D

When the jump frequency function is used, the output frequency does not change within the jump fre-
quency range.

D

Check to be sure that the jump frequency (constants d3-01 to d3-03) and jump frequency width (constant
d3-04) settings are suitable.

J

The frequency reference upper limit has been reached.

D

The output frequency upper limit is determined by the following formula:
Maximum output frequency (E1-04)

u Frequency reference upper limit (d2-01) / 100

D

Check to be sure that the constant E1-04 and d2-01 settings are suitable.

9.2.16 Winding change error has occurred

J

T

he motor does not perform winding change.

D

Magnetic contactor excitation is not performed properly. Check power supply to magnetic contactor.

D

Magnetic contactor is wired incorrectly. Check the wiring and correct the cause.

D

Magnetic contactor is not working. Replace the magnetic contactor with a new one.

D

The winding change signals are not received properly (When winding change is selected. ) Check the
constant settings.

D

Winding change frequency (P1-01) and winding change hysteresis (P1-02) are not set properly. Adjust
the constant settings.

D

Max. output frequency (E1-04) and Motor 2 max. output frequency are not set properly. Adjust the set-
tings.

J

C

licking sound from magnetic contactor

D

One of the following constants is not set properly : Min. baseblock time (L2--03) , Voltage recovery time
(L2-04), Speed search deceleration time (b3--03), or Acceleration time (C1--01). Check the constants
and adjust the settings.

J

OV

(Overvoltage) is detected during winding change.

D

Voltage recovery time (L2-04) is set too low. Verify the setting.

J

O

C (Overcurrent) is detected during winding change.

D

Either Min. baseblock time (L2-03) or Voltage recovery time (L2-04) is set too low. Verify the settings.

9