8.2

Programming Mode Constants

- 11

J

Factory Tuning: C8

Constant

Name

Setting

Factory

Change

during

Control Methods

Constant

Number

Display

Description

Setting

Range

Factory

Setting

g

during

Opera-

tion

Open Loop

Vector

Flux Vector

Page

C8-08

AFR gain

Sets the internal speed feedback
detection control section as a ratio.

Usually setting is not necessary.

Adjust in the following circum-
stances:

S When hunting occurs, increase

0.00 to

1 00

A

5

C8-08

AFR Gain

When hunting occurs, increase

the set values.

S When responsiveness is low, de-

crease the set values.

Change the responsiveness in 0.05
units at a time, checking after each
change.

0.00 to

10.00

1.00

A

- 5

C8-09

Speed feedback
detection control
(ARF) time

S Increase setting if hunting occurs.
S Decrease setting if response is

0 to

2000

50

A

----

AFR Time

g

p

poor.

2000

C8-30

Carrier frequency
selection during auto-
tuning

0: Carrier frequency is set to

2.0 kHz.

1: Carrier frequency is set to a value

as set in C6 01

0 to 2

2

A

----

Carrier in tune

as set in C6-01.

2: Carrier frequency is set to 5 kHz.

8.2.3 Reference Constants: d

J

Preset Reference: d1

Constant

Name

Setting

Factory

Change

during

Control Methods

Constant

Number

Display

Description

Setting

Range

Factory

Setting

g

during

Opera-

tion

Open Loop

Vector

Flux Vector

Page

d1-01

Frequency reference
1

Sets the frequency reference in the
units used in o1-03 (frequency ref-
erence display/set units ) The facto-

0.00

Q

Q

- 8

d1 01

Reference 1

erence display/set units.) The facto-
ry setting unit for o1-03 is Hz.

0.00

Q

Q

- 8

d1-02

Frequency reference
2

The frequency reference when the
multi-function input “multi-step

0.00

Q

Q

- 8

d1 02

Reference 2

multi function input multi step
speed reference 1” is ON.

0.00

Q

Q

- 8

d1-03

Frequency reference
3

The frequency reference when the
multi-function input “multi-step

0.00

Q

Q

- 8

d1 03

Reference 3

multi function input multi step
speed reference 2” is ON.

0.00

Q

Q

- 8

d1-04

Frequency reference
4

The frequency reference when the
multi-function input “multi-step

0.00

Q

Q

- 8

d1 04

Reference 4

multi function input multi step
speed reference 1, 2” is ON.

0.00

Q

Q

- 8

d1-05

Frequency reference
5

The frequency reference when the
multi-function input “multi-step

0 to

400 00

0.00

B

B

- 8

d1 05

Reference 5

multi function input multi step
speed reference 3” is ON.

0 to

400.00

0.00

B

B

- 8

d1-06

Frequency reference
6

The frequency reference when the
multi-function input “multi-step

0.00

B

B

- 8

d1 06

Reference 6

multi function input multi step
speed reference 1, 3” is ON.

0.00

B

B

- 8

d1-07

Frequency reference
7

The frequency reference when the
multi-function input “multi-step

0.00

B

B

- 8

d1 07

Reference 7

multi function input multi step
speed reference 2, 3” is ON.

0.00

B

B

- 8

d1-08

Frequency reference
8

The frequency reference when the
multi-function input “multi-step

0.00

B

B

- 8

d1 08

Reference 8

multi function input multi step
speed reference 1, 2, 3” is ON.

0.00

B

B

- 8

d1-09

Jog frequency refer-
ence

The frequency reference when the
multi-function inputs, “Jog frequen-
cy reference selection,” “FJOG

6.00

Q

Q

- 8

d1 09

Jog Reference

cy reference selection,

FJOG

command,” and “RJOG command”
are ON.

6.00

Q

Q

- 8

8

Advertising