IL - Immediate Low Output

Compatibility: All drives
See also:

IH, SO commands.

Sets an output low (closed) immediately. Use SO instead if you don’t want the output to change until a buffered
command (like a move) is complete.

Command Details:

Structure

IL(Parameter #1)

Type

IMMEDIATE

Usage

WRITE ONLY

Non-Volatile

NO

Register Access

None

Parameter Details:

(See Appendix F: Working With Inputs and Outputs)

Examples:

Command

Drive sends

Notes

IL1

-

Output 1 goes low immediately

IL2

-

Output 2 goes low immediately

To force Outputs on main driver board when using an SE, QE, or Si drive
ILY1

-

Output 1 of main driver board goes low immediately

ILY2

-

Output 2 of main driver board goes low immediately