Led and 7-segment display codes, Bludc led codes, Bluac 7-segment codes – Applied Motion RS-232 User Manual

Page 256

Advertising
background image

256

920-0002 Rev. I
2/2013

Host Command Reference

LED and 7-Segment Display codes

In addition to the Alarm and Status codes, most drive alarms and faults as well as some status codes

are displayed at the front of the drives, via either two-color flashing LED codes or 7-segment LED codes. The
following tables show the various codes available with Applied Motion drives.

BLuDC LED codes

Items in

bold italic are Drive Faults.

DESCRIPTION

-

solid

Motor disabled

-

flashing

slowly

Motor enabled

-

flashing

quickly

Q program running (Q drives only)

1

1

position limit

1

2

move attempted while disabled

2

1

CCW limit

2

2

CW limit

3

1

over temperature (> 85 deg C)

3

2

bad flash

4

1

over voltage (> 55 Vdc)

4

2

under voltage (< 18 Vdc)

5

1

over current / short circuit

5

2

current limit

6

1

bad hall

6

2

bad encoder

7

1

serial communication error

BLuAC 7-Segment codes

Items in

bold italic are Drive Faults.

Position Mode

Over Temp

Comm Error

Velocity Mode

Over Voltage

Move attempted while
disabled

Torque Mode

Under Voltage

Drive Start-up

Step Mode

Over Current

Bad Flash

Si Mode

Current Limit

Comm Time-out

Advertising