107

920-0002 Rev. I

2/2013

Host Command Reference

IS - Input Status

Compatibility: All drives

Requests immediate status of all drive inputs. A closed input is represented by a “0” (zero), and an open input is
represented by a “1” (one). Unused positions in the response are represented by “0” (zero).

BLu, STAC6

On S and Q drives the IS command requests the status of IN/OUT1 or main driver board (DB-25) inputs X1
through X7 plus the encoder index channel (if present). On SE, QE, and Si drives the ISX command (IS
command with parameter character X) is required to request status of IN/OUT1 or main driver board (DB-25)
inputs X1 through X7 plus the encoder index channel (if present), while IS requests IN/OUT2 or top board (screw
terminal) inputs 1 through 8.

SV, ST-Q/Si

The IS command requests the status of inputs X1 through X8 plus the encoder index channel (if present).

ST-S, STM17-S/Q/C, STM23-Q/C, STM24-C

The IS command requests the status of all three digital inputs, STEP, DIR, and EN, plus the encoder index
channel (STM only, if present).

STM17-C, STM24-C

The IS command requests the status of all three digital inputs, IN1, IN2, and IN3, plus the encoder index channel,
if present.

Command Details:

Structure

IS{Parameter #1}

Type

IMMEDIATE

Usage

READ ONLY

Non-Volatile

NO

Register Access

None

Parameter Details:

BLu, STAC6

Parameter #1

Optional “X” character used to access driver board inputs
with SE, QE, and Si drives.

SV, ST-Q/Si, ST-S, STM17-S/Q/C, STM23-Q/C, STM24-C

Parameter #1

“X” character ignored if used.

SVAC3, STAC5

Parameter #1

Optional “X” character used to access driver board inputs
with Q and IP drives.