Host Command Reference

RX - Register Load - buffered

Compatibility: Q drives only
Affects:

All data registers

See also:

RL, RU, RM commands

Sets a data register to the given immediate data value. The data value is checked and stored as a Long word.
When loading a Short-word data register with the given Long-word data value only the lower word of the Long
value is used. This command is the same as the RL command except it is a buffered command and therefore can
be placed in a stored program.

Command Details:

Structure

RX(Parameter #1)(Parameter #2)

Type

BUFFERED

Usage

READ/WRITE

Non-Volatile

NO

Register Access

All data registers

Parameter Details:

Parameter #1

Data register assignment

- units

character

- range

All Read/Write and User-Defined data registers; Read-
Only data registers can be used when Parameter #2 is not
included (i.e. for reading back the contents of a Read-Only
data register)

Parameter #2

Data register value

- units

integer

- range

+/- 2147483647 (long data registers)
+/- 32767 (short data registers)

Examples:

Command

Drive sends

Notes

RXA100

-

Set acceleration register “A” to 1000 rpm/s

RXA RXA=100