Rw - register write, Command details, Parameter details – Applied Motion RS-232 User Manual

Page 186: Examples

Advertising
background image

186

920-0002 Rev. I
2/2013

Host Command Reference

RW - Register Write

Compatibility: Q drives only
Affects:

All data registers

See also:

RI, RD, RL, RM, RW commands

Writes the data value of a given data register into non-volatile memory. The data value is written as a Long word.
See Appendix A for more details on this command, including its limitations.

NOTE: The RW function writes information to flash memory, which has a useful life of 10,000 write cycles.

Command Details:

Structure

RW(Parameter #1)(Parameter #2)

Type

BUFFERED

Usage

WRITE ONLY

Non-Volatile

NO

Register Access

All Read/Write and User-Defined data registers

Parameter Details:

Parameter #1

Data register assignment

- units

character

- range

all Read/Write and User-Defined data registers

Parameter #2

Non-volatile memory location

- units

integer

- range

1 - 100

Examples:

Command

Drive sends

Notes

RWV10

-

Write data from data register “V” into non-volatile memory location #10

Advertising
This manual is related to the following products: