Host Command Reference

AT - Analog Threshold

Compatibility: All drives
Affects:

All “Feed to Sensor” type commands

See also:

AF, AZ, FS, FY, FD commands

Sets or requests the Analog Input Threshold that is used by the “Feed to Sensor” command. The threshold value
sets the Analog voltage that determines a sensor state or a trigger value.

Command Details:

Structure

AT{Parameter #1}

Type

BUFFERED

Usage

READ/WRITE

Non-Volatile

YES

Register Access

“Y” (041)

Parameter Details:

Parameter #1

Analog threshold value

- units

volts

- range

BLu, SV, STAC6, ST-Q/Si, STAC5, SVAC3: -10.000 to
10.000
ST-S, STM: 0.000 to 5.000

Examples:

Command

Drive sends

Notes

AT4.5

-

Analog input threshold set to 4.5 volts

AT AT=4.5