AL - Alarm Code

Compatibility: All drives
See also:

AI, AR, AX commands, Appendix

Reads back an equivalent hexadecimal value of the Alarm Code’s 16-bit binary word.

Command Details:

Structure

AL

Command Type

IMMEDIATE

Usage

READ ONLY

Non-Volatile

NO

Register Access

“f” (054)
Note: response to AL command is a different format than
the response to the RLf command. See Appendix F for
details.

Units

Hexadecimal value of 16-bit binary word (see below)

Response Details:

Hex Value

BLu

SV

STAC6

ST

STM

0001

Position Limit

0002

CCW Limit

0004

CW Limit

0008

Over Temp

0010

Excess Regen*

Internal Voltage

Excess Regen

Internal Voltage

Internal Voltage

0020

Over Voltage

0040

Under Voltage*

Under Voltage

Under Voltage

Under Voltage

Under Voltage

0080

Over Current

0100

Bad Hall Sensor

Open Motor Winding

0200

Bad Encoder

(not used)

0400

Comm Error

0800

Bad Flash

1000

Wizard Failed

No Move

2000

Current Foldback

Motor Resistance

Out of Range

(not used)

(not used)

4000

Blank Q Segment

8000

No Move

(not used)

* BLuAC drives only
NOTE: Items in

bold italic represent Drive Faults, which automatically disable the motor. Use the OF

command in a Q Program to branch on a Drive Fault.
NOTE: See Appendix for more detailed information on Alarm Codes.

Examples:

Command

Drive sends

Notes

AL

AL=0000

No alarms

AL

AL=0001

Position limit alarm

AL

AL=0201

Position limit and bad encoder signal alarms