Cg - anti-resonance filter gain, Command structure, Command details – Applied Motion RS-232 User Manual

Page 50: Parameter details, Examples

Advertising
background image

50

920-0002 Rev. I
2/2013

Host Command Reference

CG - Anti-resonance Filter Gain

Compatibility: Stepper drives only
Affects:

Mid-range performance of step motors

See also:

CF command

Sets or requests the anti-resonance filter gain setting. This setting is unit-less and works in conjunction with the
anti-resonance filter frequency setting (CF) to cancel instabilities due to mid-band resonance.

NOTE: We strongly suggest using the appropriate Configurator software application to set this value by entering
as accurate a load inertia value as possible in the motor settings window.

Command Structure:

CG{Parameter #1}

Command Details:

Structure

CG{Parameter #1}

Type

BUFFERED

Usage

READ/WRITE

Non-Volatile

YES

Register Access

None

Parameter Details:

Parameter #1

Filter gain

- units

integer number

- range

0 - 32767

Examples:

Command

Drive sends

Notes

CG800

-

Set anti-resonance filter gain to 800

CG CG=800

Advertising
This manual is related to the following products: