RO - Anti-Resonance ON

Compatibility: Stepper drives

Enables or disables the Anti-Resonance algorithm. This command has the same effect as the “Anti-Resonance
off” check box in ST Configurator’s motor configuration dialog.

Command Details:

Structure

RO{Parameter #1}

Type

BUFFERED

Usage

READ / WRITE

Non-Volatile

YES

Register Access

None

Parameter Details:

Parameter #1

Anti-Resonance Algorithm Status

- units

integer

- range

0 (Anti-Resonance OFF)
1 (Anti-Resonance ON)

Examples:

Command

Drive sends

Notes

RO1

-

Enable Anti-Resonance algorithm

RO RO=1

RO0

-

Disable Anti-Resonance algorithm

RO RO=0