CR - Compare Registers

Compatibility: Q drives only
Affects:

Contents of condition code register “h”

See also:

RI, RD, RM, RL, QJ commands

Compare the contents of two data registers. The first data register (Parameter #1) is tested by comparing it
against the data value in the second data register (Parameter #2). The result is a condition code that can be used
for program conditional processing (see QJ command). For Example, if the first data register is greater than the
second the “greater than” flag is set and the QJGx command can be used to create a conditional jump.

Command Details:

Structure

CR(Parameter #1)(Parameter #2)

Type

BUFFERED

Usage

WRITE ONLY

Non-Volatile

NO

Register Access

All data registers

Parameter Details:

Parameter #1

First data register assignment

- units

character

- range

All data register assignments

Parameter #2

Second data register assignment

- units

character

- range

All data register assignments

Examples:

Command

Drive sends

Notes

CRE1

-

Compare data register “E” to data register “1”

QJG5

-

If “E” register is greater than “1” register jump to line 5 of Q segment,

otherwise proceed to next line.