Rr - register read, Command details, Parameter details – Applied Motion RS-232 User Manual

Page 182: Examples

Advertising
background image

182

920-0002 Rev. I
2/2013

Host Command Reference

RR - Register Read

Compatibility: Q drives only
Affects:

All data registers

See also:

RI, RD, RL, RM, RW commands

Reads a data value from a non-volatile memory location into a data register. The data value is read as a Long
word. If the value being read is too large for the destination data register, the value is truncated.

Command Details:

Structure

RR(Parameter #1)(Parameter #2)

Type

BUFFERED

Usage

WRITE ONLY

Non-Volatile

NO

Register Access

All Read/Write and User-Defined data registers

Parameter Details:

Parameter #1

Data register

- units

character

- range

all Read/Write and User-Defined data registers

Parameter #2

Non-volatile memory location

- units

integer

- range

1 - 100

Examples:

Command

Drive sends

Notes

RRV10

-

Read data from non-volatile memory location #10 and place it in data

register “V”