shows the 16 bit assignments for the Alarm Code (which of course match the hexadecimal values above).

Example: The drive has hit the CW limit (bit 2), there is an under voltage condition (bit 6), and an encoder

wiring connection has been lost resulting in an encoder fault (bit 9). The resulting Alarm Code binary word is 0000
0010 0100 0100. The decimal equivalent of this word is 580, so the response from the drive to the RLf command
will be “RLf=580”.

Status Code Definitions

SC command

When a host sends the SC command, the response from the drive will be the Hexadecimal equivalent of

a 16-bit word. This hexadecimal value is considered the Status Code, and the hexadecimal value for each of
the bits in the Status Code is given below. When a host sends the SC command, the response from the drive
will actually be the Hexadecimal equivalent of this 16-bit word. This hexadecimal value is considered the Status
Code, and the equivalent hexadecimal value for each of the bits is given below.

Hex Value

Status Code bit definition

0001

Motor Enabled (Motor Disabled if this bit = 0)

0002

Sampling (for Quick Tuner)

0004

Drive Fault (check Alarm Code)

0008

In Position (motor is in position)

0010

Moving (motor is moving)

0020

Jogging (currently in jog mode)

0040

Stopping (in the process of stopping from a stop command)

0080

Waiting for an input (executing WI command)

0100

Saving (parameter data is being saved)

0200

Alarm present (check Alarm Code)

0400

Homing (executing an SH command)

0800

Wait Time (executing a WT command)