Sf - step filter frequency, Command details, Parameter details – Applied Motion RS-232 User Manual

Page 197: Examples

Advertising
background image

197

920-0002 Rev. I

2/2013

Host Command Reference

SF - Step Filter Frequency

Compatibility: Stepper drives only

Sets or requests the step filter frequency. The primary use of this filter is to introduce “microstep emulation”
effects, which smooth out low resolution step pulses when the drive’s microstep/gearing resolution (EG command)
is set to a low value. This command is exceptionally useful when using a low-resolution indexer and smooth motor
shaft rotation is required.

Command Details:

Structure

SF{Parameter #1}

Type

BUFFERED

Usage

READ/WRITE

Non-Volatile

Yes

Register Access

None

Parameter Details:

Parameter #1

Step filter frequency

- units

Hz

- range

0 - 2500

Examples:

Command

Drive sends

Notes

SF500

-

Set step filter frequency to 500 Hz

SF SF=500