Host Command Reference

RM - Register Move

Compatibility: Q drives only
Affects:

All data registers

See also:

RI, RD, RL, TR, RX commands

Move the contents of a first data register into a second data register.

Command Details:

Structure

RM(Parameter #1)(Parameter #2)

Type

BUFFERED

Usage

WRITE ONLY

Non-Volatile

NO

Register Access

All Read/Write and User-Defined data registers

Parameter Details:

Parameter #1

Source data register

- units

character

- range

all data register assignments

Parameter #2

Destination data register

- units

character

- range

all Read/Write and User-Defined data registers

Examples:

Command

Drive sends

Notes

RMAB

-

Move contents of acceleration register “A” into the deceleration

register “B”