Zr - regen resistor value, Command details, Parameter details – Applied Motion RS-232 User Manual

Page 224: Examples

Advertising
background image

224

920-0002 Rev. I
2/2013

Host Command Reference

ZR - Regen Resistor Value

Compatibility: BLuAC5 and STAC6 drives only

Sets or requests the regeneration resistor value. BLuAC and STAC drives dynamically calculate the continuous
wattage induced into an external regeneration resistor and must know the value of the regen resistor to do this
effectively.

Command Details:

Structure

ZR{Parameter #1}

Type

BUFFERED

Usage

READ/WRITE

Non-Volatile

Yes

Register Access

None

Parameter Details:

Parameter #1

Value of regen resistor

- units

Ohms

- range

25 - 100

Examples:

Command

Drive sends

Notes

ZR50

-

50 ohm external regen resistor connected to drive