Ia - immediate analog, Command details, Parameter details – Applied Motion RS-232 User Manual

Page 95

Advertising
background image

95

920-0002 Rev. I

2/2013

Host Command Reference

IA - Immediate Analog

Compatibility: All drives
See Also:

AD, AV, AZ and IF commands

BLu, SV, STAC6, ST-Q/Si

Requests present analog input value from the given source. There are three different analog values that can be
accessed. With no parameter the IA command returns the Analog Command value which is derived from the
analog inputs with gain and offset values applied as set in Quick Tuner or Configurator or via the AD, AV and/or
AZ commands. When a parameter is given raw (unscaled) analog input values are returned.

ST-S, STM

Requests present analog input value. There are two different analog values that can be accessed. With no
parameter the IA command returns the Analog Command value which is derived from the analog input with gain
and offset values applied as set in ST Configurator or via the AD, AV and/or AZ commands. When a parameter is
given raw (unscaled) analog input values are returned.

Note: The output of the IA command is formatted by IF. See IF for further details.

Command Details:

Structure

IA{Parameter #1}

Type

IMMEDIATE

Usage

READ ONLY

Non-Volatile

NO

Register Access

All drives...
“a” (049) Analog Command

BLu, SV, STAC6, ST-Q/Si...
“j” (058) Analog input 1 (unscaled)
“k” (059) Analog input 2 (unscaled)

ST-S, STM...
“j” (058) AIN (unscaled)

Parameter Details:

BLu, SV, STAC6, ST-Q/Si, STAC5, SVAC3

Parameter #1

Analog input

- units

integer

- range

No parameter or 0 = Analog command
1 = Analog input 1 (unscaled)
2 = Analog input 2 (unscaled)
3 = Expanded analog input (SE, QE, and Si models)

ST-S, STM17-S/Q/C, STM23-Q

Parameter #1

Analog input

- units

integer

- range

No parameter or 0 = Analog command
1 = AIN (unscaled)

Advertising