PT - Pulse Type

Compatibility: All drives
See also:

CM, EG commands

Sets or requests the type of incoming pulse used in CM7 (Pulse and Direction mode).

The possible input signals are as follows:

0 = Step / Direction

1 = CW / CCW Pulse

2 = AB Quadrature (master encoder)

4 = Step / ~Direction (direction input is reversed from PT0)

6 = BA Quadrature (count direction is reverse of PT2)

Command Details:

Structure

PT{Parameter #1}

Type

BUFFERED

Usage

READ / WRITE

Non-Volatile

YES

Register Access

None

Parameter Details:

Parameter #1

Pulse Type

- units

integer

- range

0, 1, 2, 4, or 6

Examples:

Command

Drive sends

Notes

PT0

-

Instruct the drive to follow step/direction pulses from a master controller.

PT PT=0

PT2

-

Instruct the drive to follow AB quadrature encoder pulses, typically from a

master encoder.

PT PT=2