Examples – Applied Motion RS-232 User Manual

Page 69

Advertising
background image

69

920-0002 Rev. I

2/2013

Host Command Reference

Examples:

Command

Drive sends

Notes

EF1

-

Turn ON Stall Detection function

EF EF=1

EF6

-

Enable Stall Prevention with time-out

EF EF=6

Example encoder alignment sequence (STM24):

CC6

Raise current to 6A

CI5.4

Raise idle current to 5.4A*

EF1

Enable Stall Detection feature

CC3

Lower current to normal running level (application dependent)

CI2.4

Lower idle current to normal running level (application dependent)

If this is done through a Q program, add a short delay after raising current levels:

CC6

Raise current to 6A

CI5.4

Raise idle current to 5.4A*

WT1

Short delay

EF1

Enable Stall Detection feature

CC3

Lower current to normal running level (application dependent)

CI2.4

Lower idle current to normal running level (application dependent)

* 90% of CC; see CI command for details

Advertising