Di - distance/position, Command details, Parameter details – Applied Motion RS-232 User Manual

Page 63: Examples

Advertising
background image

63

920-0002 Rev. I

2/2013

Host Command Reference

DI - Distance/Position

Compatibility: All drives
Affects:

All move commands

See also:

AC, DC, DE and VE commands

Sets or requests the move distance in encoder counts (servo) or steps (stepper). The sign of DI indicates move
direction: no sign means CW and “-” means CCW. DI sets both the distance for relative moves, like FL, and the
position for absolute moves, like FP. DI also sets the direction of rotation for jogging (CJ).

Command Details:

Structure

DI{Parameter #1}

Type

BUFFERED

Usage

READ/WRITE

Non-Volatile

YES

Register Access

“D” (020)

Parameter Details:

Parameter #1

distance

- units

encoder counts (servo) or steps (stepper)

- range

-2,147,483,647 to 2,147,483,647
sign determines direction: “-” for CCW, no sign for CW

Examples:

Command

Drive sends

Notes

DI20000

-

Set distance to 20000 counts in the CW direction

DI DI=20000

DI-8000

-

Set distance to 8000 counts in the CCW direction

FL

-

Initiate FL move

Advertising