91

920-0002 Rev. I

2/2013

Host Command Reference

HG - 4th Harmonic Filter Gain

Compatibility: Stepper drives only
Affects:

Low-speed performance of step motors

See also:

HP command

Sets or requests the 4th harmonic filter gain setting. This setting works in conjunction with the 4th harmonic filter
phase setting (HP) to reduce low-speed torque ripple in step motors.

NOTE: We strongly suggest you set this value in the ST Configurator software application only.

Command Details:

Structure

HG{Parameter #1}

Type

IMMEDIATE

Usage

READ/WRITE

Non-Volatile

YES only when set in Configurator software, otherwise NO

Register Access

None

Parameter Details:

Parameter #1

Filter gain

- units

integer number

- range

0 - 32767

Examples:

Command

Drive sends

Notes

HG8000

-

Set filter gain value to 8000

HG HG=8000