St-q/si led codes, St-s led codes – Applied Motion RS-232 User Manual

Page 258

Advertising
background image

258

920-0002 Rev. I
2/2013

Host Command Reference

1

1

motor stall (w/ optional encoder only)

1

2

move attempted while disabled

2

1

CCW limit

2

2

CW limit

3

1

over temp

3

2

excess regen

4

1

over voltage

4

2

under voltage

4

3

Bad Si program instruction

5

1

over current / short circuit

5

2

motor resistance out of range

6

1

open motor winding

6

2

bad encoder signal (w/ optional encoder only)

7

1

serial communication error

ST-Q/Si LED codes

Items in

bold italic are Drive Faults.

DESCRIPTION

-

solid

Motor disabled

-

flashing slowly

Motor enabled

-

flashing quickly Q program running (Q drives only)

1

1

motor stall (w/ optional encoder only)

1

2

move attempted while disabled

2

1

CCW limit

2

2

CW limit

3

1

over temp

3

2

internal voltage out of range

4

1

over voltage

4

2

under voltage

4

3

Bad Si program instruction

5

1

over current / short circuit

6

1

open motor winding

6

2

bad encoder signal (w/ optional encoder only)

7

1

serial communication error

ST-S LED codes

Items in

bold italic are Drive Faults.

DESCRIPTION

-

solid

Motor disabled

-

flashing slowly

Motor enabled

Advertising