Sk - stop & kill, Command details, Parameter details – Applied Motion RS-232 User Manual

Page 202: Examples

Advertising
background image

202

920-0002 Rev. I
2/2013

Host Command Reference

SK - Stop & Kill

Compatibility: All drives
See Also:

AM, DE, JA, ST, SM commands

Halts any buffered command in progress and removes any other buffered commands from the queue. When used
to stop a move deceleration rate is controlled by the AM (Max Acceleration) parameter. If the “D” parameter is
used deceleration rate is controlled by either DE (with “Feed” moves like FL, FP, SH) or JA (when jogging).

Command Details:

Structure

SK{Parameter #1}

Type

IMMEDIATE

Usage

WRITE ONLY

Non-Volatile

NO

Register Access

None

Parameter Details:

Parameter #1

Deceleration rate

- units

letter

- range

D = deceleration rate set by DE or JA command
no parameter = deceleration rate set by AM command

Examples:

Command

Drive sends

Notes

SK

-

Stop motion immediately using the deceleration rate set by the

AM command and erase the contents of the queue

SKD

-

Stop motion immediately using the deceleration rate set by the

DE command (or JA if jogging) and erase the contents of the queue

Advertising
This manual is related to the following products: