CD - Idle Current Delay Time

Compatibility: Stepper drives only
Affects:

Motor current at rest

See also:

CC, CI commands

Sets or requests the amount of time the drive will delay before transitioning from full current (CC) to idle current
(CI). This transition is made after a step motor takes the final step of a move. Operating in any form of pulse &
direction mode the drive will reset the idle current delay timer each time a step pulse is received by the drive.

Command Details:

Structure

CD{Parameter #1}

Type

BUFFERED

Usage

READ/WRITE

Non-Volatile

YES

Register Access

None

Parameter Details:

Parameter #1

Delay time

- units

seconds

- range

0.00 to 10.00

Examples:

Command

Drive sends

Notes

CD0.4

-

Idle current delay time set to 0.4 seconds

CD CD=0.4