Cs - change speed, Command details, Parameter details – Applied Motion RS-232 User Manual

Page 58: Examples

Advertising
background image

58

920-0002 Rev. I
2/2013

Host Command Reference

CS - Change Speed

Compatibility: All drives
Affects:

Jog speed while jogging

See also:

CJ, JS, JA, JL commands

Sets or requests the jogging speed in rev/sec while jogging. When Jogging using the CJ command the Jog speed
can be changed dynamically by using this command. The sign of CS can be positive or negative allowing the
direction of jogging to be changed dynamically also. Ramping between speeds is controlled by the JA and JL
commands. Setting CS does not change JS or DI.

Command Details:

Structure

CS{Parameter #1}

Type

IMMEDIATE

Usage

READ/WRITE

Non-Volatile

YES

Register Access

“J” (026)
Note: The CS command uses different units than the “J”
register; see Data Registers section for more details.

Parameter Details:

Parameter #1

Jog Speed

- units

rev/sec

- range

BLu, SV, STAC6, ST-Q/Si, ST-S, STAC5, SVAC3:
-133.3333 to 133.3333 (resolution is 0.0042)
STM: -80.0000 to 80.0000 (resolution is 0.0042)
sign determines direction: “-“ for CCW, no sign for CW

Examples:

Command

Drive sends

Notes

JS1

-

Set base jog speed to 1 rev/sec

CJ

-

Commence jogging

CS2.5

-

Set jog speed to CW at 2.5 rev/sec

CS

CS=2.5

Displays current Jog speed

CS-5

-

Set jog speed to CCW at 5 rev/sec

SJ

-

Stop jogging

Advertising