ZC - Regen Resistor Continuous Wattage

Compatibility: BLuAC5 and STAC6 drives only

Sets or requests the regeneration resistor wattage value. BLuAC and STAC drives dynamically calculate the
continuous wattage induced into an external regeneration resistor and must know the continuous wattage rating of
the regen resistor to do this effectively.

Command Details:

Structure

ZC{Parameter #1}

Type

BUFFERED

Usage

READ/WRITE

Non-Volatile

Yes

Register Access

None

Parameter Details:

Parameter #1

Continuous wattage value of regen resistor

- units

Watts

- range

1 - 1000

Examples:

Command

Drive sends

Notes

ZC250

-

External regen resistor with value of 250 continuous watts is

connected to the drive