Host Command Reference

Exceptions:

•

When using the Follow Encoder or Hand Wheel commands (FE or HW, respectively), the master encoder
channels A and B must be wired to drive inputs STEP/X1/IN1 and DIR/X2/IN2. In these modes, these
inputs must not be used for sensor inputs.

•

Using the On Input (OI) command with no parameter will disable the interrupt function.

•

The Seek Home (SH) command makes use of the drive’s CW and CCW limit functions. As such, the
home sensor may not be wired to the following inputs:

STAC5-S:

X1, X2

STAC5-Q/IP:

IN7, IN8

SVAC3-S:

X1, X2

SVAC3-Q/IP:

IN7, IN8

BLu:

X6, X7

STAC6:

X6, X7

ST-S/Plus:

STEP, DIR

ST-Q/Si/C/IP:

X7, X8

SV7:

X7, X8

STM17-S/Q:

STEP, DIR

STM17-C:

IN1, IN2

STM23-S/Q:

STEP, DIR

STM23-C:

IN1, IN2

STM24-SF/QF:

I/O3, I/O4

STM24-C:

IN1, IN2

Output Parameter Details

BLu-S, BLu-Q
STAC6-S, STAC6-Q, STAC6-C

Parameter #1

Optional “Y”, output number, output condition
NOTE: Including/omitting the optional “Y” has no effect on the execution
of the command.

- units

Optional “Y”, integer, letter

- range

- integer: 1 - 3

- letter: L = Low, H = High

BLu-SE, BLu-QE, BLu-Si
STAC6-SE, STAC6-QE, STAC6-Si

Parameter #1

Optional “Y”, output number, output condition
NOTE: Including the optional “Y” indicates that the output(s) resides on
the IN/OUT1 or main drive board connector. Omitting the “Y” indicates
that the output(s) resides on the IN/OUT2 or top board connector.

- units

Optional “Y”, integer, letter

- range

- integer for IN/OUT1 or main drive board connector: Y1 - Y3
- integer for IN/OUT2 or top board connector: 1 - 4

- letter: L = Low, H = High