So - set output, Command details, Parameter details – Applied Motion RS-232 User Manual

Page 204: Examples

Advertising
background image

204

920-0002 Rev. I
2/2013

Host Command Reference

SO - Set Output

Compatibility: All drives
See Also:

IL, IH, IO commands

Sets an output to the given condition. Care must be taken when using outputs on the main driver board because
those outputs are by default programmed for dedicated purposes (Alarm, Brake, Motion). Use the AO, BO and
MO commands to reconfigure main driver board output usage to general purpose before using the SO command
with those outputs.

Command Details:

Structure

SO(Parameter #1)

Type

BUFFERED

Usage

WRITE ONLY

Non-Volatile

NO

Register Access

None

Parameter Details:

(See Appendix F: Working With Inputs and Outputs)

Examples:

Command

Drive sends

Notes

SO1L

-

Set output 1 low (closed)

SO2H

-

Set output 2 high (open)

SOY1L

-

Set main driver board output 1 low (closed)

SOY2H

-

Set main driver board output 2 high (open)