Command details, Parameter details, Examples – Applied Motion RS-232 User Manual

Page 76

Advertising
background image

76

920-0002 Rev. I
2/2013

Host Command Reference

Command Details:

Structure

FC{Parameter #1}{Parameter #2}

Type

BUFFERED

Usage

WRITE ONLY

Non-Volatile

NO

Register Access

None

Parameter Details:

(See Appendix F: Working With Inputs and Outputs)

Examples:

Command

Drive sends

Notes

DI50000

-

Set distance to 50000 steps

VE5

-

Set velocity to 5 rps

DC40000

-

Set change distance to 40000 steps

VC0.5

-

Set change velocity to 0.5 rps

FC

-

Initiate move

FC with I/O trigger
DI50000

-

Set distance to 50000 steps

VE5

-

Set velocity to 5 rps

DC40000

-

Set change distance to 40000 steps

VC0.5

-

Set change velocity to 0.5 rps

FC1L

-

Initiate move, specifying that the drive will move 50000 steps

beyond the point where input 1 goes LOW.

For Q drives only
MT1

-

Turn multi-tasking ON*

DI50000

-

Set overall move distance to 50000 steps

VE5

-

Set initial velocity to 5 rps

DC10000

-

Set 1st change distance to 10000 steps

VC10

-

Set 1st change velocity to 10 rps

FC

-

Initiate move

WP

-

Wait position

DC20000

-

Set 2nd change distance to 20000 steps

VC1

-

Set 2nd change velocity to 1 rps

WP

-

Wait position

DC30000

-

Set 3rd change distance to 30000 steps

VC0.5

-

Set 3rd change velocity to 0.5 rps

* Because multi-tasking is required for the WP command to be used, only Q models can perform multi-
segment moves.

Advertising