RL - Register Load - immediate

Compatibility: All drives
Affects:

All data registers

See also:

RX, RI, RD, RM commands

Sets a data register to the given immediate data value. The data value is checked and stored as a Long word.
When setting a Short-word register with the given Long-word data value only the lower word of the Long value is
used.

Command Details:

Structure

RL(Paramter #1){Parameter #2}

Type

IMMEDIATE

Usage

READ/WRITE

Non-Volatile

NO

Register Access

All data registers

Parameter Details:

Parameter #1

Data register assignment

- units

character

- range

All Read/Write and User-Defined data registers; Read-
Only data registers can be read back when Parameter #2
is not included

Parameter #2

Data register value

- units

integer

- range

+/- 2147483647 (long data registers)
+/- 32767 (short data registers)

Examples:

Command

Drive sends

Notes

RLA100

-

Set acceleration register to 1000 rpm/s

RLA

RLA=100

Return acceleration register value

When PR command Bit 5 is set
RL017100

-

Set Acceleration register to 1000 rpm/s

RL017

RLA=100

Return acceleration register value

NOTE: When setting a register no pre-processing of the data value is performed. Data is set to the internal raw
value. For example, the internal raw acceleration value is in tens of rpm/s. See the “Data Register” section at
the beginning of this manual for more details on data register assignments and units.

Units Example:
AC10 means 10 rps/s
RLA10 means 10 * 10 rpm/s = 1.667 rps/s
Multiply the desired rps/s value times 6 to convert to the “raw” acceleration value