Dr - data register for capture, Command details, Parameter details – Applied Motion RS-232 User Manual

Page 66: Examples

Advertising
background image

66

920-0002 Rev. I
2/2013

Host Command Reference

DR - Data Register for Capture

Compatibility: Q servo drives only (BLu-Q and SV-Q)
Affects:

Quick Tuner Data Capture

Sets or requests the data register used in the register plot data source in Quick Tuner. Any data register can be
selected for viewing when capturing data using Quick Tuner.

Command Details:

Command Type

BUFFERED

Usage

WRITE ONLY

Non-Volatile

NO

Register Access

All data registers

Parameter Details:

Parameter #1

Data register assignment

- units

character

- range

All data register assignments

Examples:

Command

Drive sends

Notes

DRa

-

Set capture data register to “a” (Analog Command) register

Advertising