Applied Motion RS-232 User Manual

Page 307

Advertising
background image

307

920-0002 Rev. I

2/2013

Host Command Reference

Register
Name

Use

equivalent SCL command

Code Size

Read Only

p

Q segment

0x70

short

yes

q

actual current

IQ

0x71

short

yes

r

average regen power

0x72

short

yes

s

status code

SC

0x73

short

yes

t

drive temperature

IT

0x74

short

yes

u

bus voltage

IU

0x75

short

yes

v

actual velocity

IV0

0x76

short

yes

w

target velocity

IV1

0x77

short

yes

x

position error

IX

0x78

long

yes

y

IN/OUT 2 inputs

IS

0x79

short

yes

z

phase error

0x7A

short

yes

A

accel rate

AC

0x41

short

B

decel rate

DE

0x42

short

C

change distance

DC

0x43

long

D

distance

DI

0x44

long

E

position offset

0x45

long

F

other (misc) flags

0x46

long

G

current command

GC

0x47

short

H

analog velocity gain

0x48

short

I

input counter

0x49

long

J

jog speed

0x4A

short

K

jog accel rate

0x4B

short

L

jog decel rate

0x4C

short

M

max velocity

JS

0x4D

short

N

continuous current

CC

0x4E

short

O

idle current

CI

0x4F

short

P

absolute position command

0x50

long

Q

reserved

0x51

R

steps/rev

EG

0x52

short

S

pulse count

0x53

long

T

total count

0x54

long

U

change speed

VC

0x55

short

V

velocity

VE

0x56

short

W

time stamp

0x57

short

X

analog position gain

AP

0x58

short

Y

analog threshold

AT

0x59

short

Z

analog offset

AV

0x5A

short

Advertising
This manual is related to the following products: