Table 1: message type 1 command list – Applied Motion RS-232 User Manual

Page 296

Advertising
background image

296

920-0002 Rev. I
2/2013

Host Command Reference

Table 1: Message Type 1 Command List

For detailed SCL and Q command descriptions, please see the main section of this manual. When reading

the command descriptions in the main part of this manual, please be advised that the EtherNet/IP encapsulation
often requires that different units, and a different range of acceptable values, be used.

Command

Description

opcode (hex)

Reg code

Parameter 1

Parameter 2

Parameter 3

Parameter 4

Range ST5 /

ST10 / ST

AC5

Units

Motion Commands
AC

P_TO_P_ACCEL,

1E 0

accel rate

1..32000

10 rpm/sec

AM

MAX_ACCEL,

16 0

accel rate

1..32000

10 rpm/sec

AX

ALARM_RESET

BA 0

CJ

START_JOGGING

96 0

DC

SET_CHNG_DISTANCE

B7 0

32 bit distance or position

+/-2,147,483,647

steps

DE

P_TO_P_DECEL,

1F 0

decel rate

1..32000

10 rpm/sec

DI

SET_REL_DISTANCE

B6 0

32 bit distance or position

+/-2,147,483,647

steps

EF

ENCODER_FUNCTION

D6 0

function

0,1,2 or 4

0 = Encoder function off

1 = Stall Detection

2 = Stall Prevention

4 = Stall prevention w/ time-out

EG

Steps/rev / 2

26 0

steps/rev

100..25600

steps/rev divided by 2

EP

ENCODER_POSITION

98 0

32 bit encoder position

+/-2,147,483,647

counts

FC

P_TO_P_CHANGE

6D 0

FD

feed to double sensor

69 0

cond

2

io2

cond

1

io1

ST: X0..X8, L/H/F/R

STAC5: X0..X4, 1..8.

L/H/F/R

see IO Encoding Table

FE

FOLLOW ENCODER

CC 0

cond io

ST: X0..X8, L/H/F/R

STAC5: X0..X4, 1..8.

L/H/F/R

see IO Encoding Table

FL

feed to length (relative move) 66 0

FM

Feed to Sensor with mask

distance

6A 0

cond io

ST: X0..X8, L/H/F/R

STAC5: X0..X4, 1..8.

L/H/F/R

see IO Encoding Table

FO

feed and set output

68 0

cond io

ST: Y1..Y4, L or H

STAC5: 1..4, Y1,Y2. L

or H

see IO Encoding Table

FP

feed to position (absolute

move)

67 0

FS

Feed to Sensor

6B 0

cond io

ST: X0..X8, L/H/F/R

STAC5: X0..X4, 1..8.

L/H/F/R

see IO Encoding Table

FY

Feed to Sensor with safety

distance

6C 0

cond io

ST: X0..X8, L/H/F/R

STAC5: X0..X4, 1..8.

L/H/F/R

see IO Encoding Table

Advertising