Host Command Reference

RI - Register Increment

Compatibility: Q drives only
Affects:

All data registers

See also:

RD, RM commands

Increments by 1 the value of the designated data register.

Command Details:

Structure

RI(Parameter #1)

Type

BUFFERED

Usage

WRITE ONLY

Non-Volatile

NO

Register Access

All Read/Write and User-Defined data registers

Parameter Details:

Parameter #1

Data register assignment

- units

character

- range

all Read/Write and User-Defined data registers

Examples:

Command

Drive sends

Notes

RIV

-

Increments the value of the velocity data register “V”