Gc - current command, Command details, Examples – Applied Motion RS-232 User Manual

Page 89

Advertising
background image

89

920-0002 Rev. I

2/2013

Host Command Reference

GC - Current Command

Compatibility: Servo drives only
Affects:

Commanded motor current

See also:

CM command

Sets or requests the immediate current command for the servo motor and drive when the servo drive is set for
Command Mode 1 (CM1).

NOTE: Setting this value may make the servo motor run to a very high speed, especially if there is no load on the
motor. Take care when using this command.

Command Details:

Structure

GC{Parameter #1}

Type

IMMEDIATE

Usage

READ/WRITE

Non-Volatile

Yes

Register Access

“G” (023)

Command Details:

Parameter #1

RMS Current

- units

0.01 amps rms

- range

-2000 to +2000 (+/- 20 amps rms)

Examples:

Command

Drive sends

Notes

CM1

-

Set servo drive to Commanded Current Command Mode

GC100

-

Set current to motor at 1 A rms

GC-100

-

Set current to motor at -1 A rms (opposite direction)

Advertising