SD - Set Direction

Compatibility: Integrated Steppers with Flex I/O
Affects:

All input and output commands

See Also:

AI, AO, BO, DL, MO and SI

The Flex I/O feature allows the user to specify the direction of each I/O point. That is, to configure each as either
an input or output. SD may be used as a query if issued without a parameter. The drive will then report the
direction of each I/O point.

WARNING: The SD command allows dynamic changes to I/O behavior of the drive, and may cause
unintended interactions with other machine components if not implemented properly. Extreme caution
should be used. The SD command is documented here only for completeness; Applied Motion Products
strongly recommends that the Configurator software be used to make changes to drive I/O behavior.

Command Details:

Structure

SD{Parameter #1}{Parameter #2}

Type

BUFFERED

Usage

READ/WRITE

Non-Volatile

Yes

Register Access

None

Parameter Details:

Parameter #1

I/O point to configure

- units

Integer

- range

1 - 4

Parameter #2

Direction (input or output)

- units

Single character

- range

‘I’ or ‘O’ (letter ‘O’, not zero)

NOTE: This command requires either the letter ‘I’ (input) or ‘O’ (output) as Parameter #2. The drive’s response
however, is composed of the numbers 1 (one = input) or 0 (zero = output).

Examples:

Command

Drive sends

Notes

SD2O

-

Set I/O point 2 as an Output

SD4I

-

Set I/O point 4 as an Input

SD

SD=00000111

Drive reports that I/O points 1, 2 and 3 are inputs, 4 is an output. (Note:

on the STM24, I/O points 5-8 are unused)