Az - analog zero, Command details, Examples – Applied Motion RS-232 User Manual

Page 37

Advertising
background image

37

920-0002 Rev. I

2/2013

Host Command Reference

AZ - Analog Zero

Compatibility: All drives
Affects:

All Analog input functions

See also:

AF, AP, AV, CM & Feed commands

Activates the analog “auto offset” algorithm. It is useful in defining the current voltage present at the analog input
as the zero reference point, or offset.

Command Details:

Structure

AZ

Type

BUFFERED

Usage

WRITE ONLY

Non-Volatile

NO

Register Access

None

Examples:

Command

Drive sends

Notes

AZ

-

Start analog offset algorithm

Example: Apply 1 VDC across the AIN and GND terminals of the drive. Then send the AZ command to the
drive. Next apply 4 VDC across the AIN and GND terminals. Send the IA command and the response will be
very close to IA=3.00 (or 4 - 1 VDC).