FX - Filter select inputs

Compatibility: All drives (except STAC5, SVAC3)
Affects:

FI command on SE, QE, and Si drives

See also:

FI command

The FX command allows changing the target inputs of a drive’s digital input filters from the main board X3 through
X7 inputs to the top board IN3 through IN7 inputs. This can only be done on SE, QE, and Si drives with firmware
1.53U or later.

Command Details:

Structure

FX{Parameter #1}

Type

BUFFERED

Usage

READ/WRITE

Non-Volatile

NO

Register Access

None

Parameter Details:

Parameter #1

Digital inputs selector

- units

integer

- range

0 = top board inputs of SE, QE, and Si drives
1 = main board inputs of all drives

Examples:

Command

Drive sends

Notes

FX0

-

Cause digital input filters set by FI command to affect top board

inputs IN3 through IN7 of SE, QE, and Si drives.

FX

FX=1

Digital filters are set to be applied to main driver board inputs

X3 through X7.