Eg - electronic gearing, Command details, Examples – Applied Motion RS-232 User Manual

Page 70

Advertising
background image

70

920-0002 Rev. I
2/2013

Host Command Reference

EG - Electronic Gearing

Compatibility: All drives
Affects:

Command Mode 7, FE and HW commands

See also:

CM, ER, FE and HW commands.

BLu, SV

Sets or requests the pulses per revolution for electronic gearing. For example, with an EG value of 20000 the
servo drive will require 20000 pulses from the master pulse source to move the servo motor 1 revolution.

STAC6, ST-Q/Si, ST-S, STM

Sets or requests the desired step/microstep resolution of the step motor.

Command Details:

Structure

EG{Parameter #1}

Type

BUFFERED

Usage

READ/WRITE

Non-Volatile

YES

Register Access

“R” (034)
Note: With servo drives the EG command is equal to the
“R” register. With stepper drives the EG command is equal
to twice the “R” register.

Parameter #1

Servo = electronic gearing ratio
Stepper = step resolution

- units

Servo = counts/rev
Stepper = steps/rev

- range

Servo = 200 - 32000
Stepper = 200 - 51200

Examples:

Command

Drive sends

Notes

EG20000

-

Set electronic gearing resolution in servo drive to 20000 pulses/rev

EG EG=20000
RLR

RLR=20000

“R” register matches the EG setting in a servo drive

EG36000

-

Set microstep resolution to 36000 steps/rev in a stepper drive

EG EG=36000
RLR

RLR=18000

“R” register contains 1/2 the EG setting in a stepper drive, or 18000

steps/rev