Applied Motion RS-232 User Manual

Page 262

Advertising
background image

262

920-0002 Rev. I
2/2013

Host Command Reference

STAC5-Q, STAC5-IP
SVAC3-Q, SVAC3-IP

Parameter #1

Optional “X”, input number, input condition
NOTE: Including the optional “X” indicates that the input(s) resides on
the IN/OUT1 connector (DB-15). Omitting the “X” indicates that the
input(s) resides on the OPT2 connector (DB-25).

- units

Optional “X”, integer, letter

- range

- integer for IN/OUT1 connector: X0 (encoder index, if present),
X1 - X4, X8 (AIN)

- integer for OPT2 connector: 1 - 8

- letter: L = Low, H = High, F = Falling Edge, R = Rising Edge

For those commands with Parameter #2

input number, input condition

- units

integer, letter

- range

- integer for IN/OUT1 connector: 0 (encoder index, if present),
1 - 4, 8 (AIN)

- integer for OPT2 connector: 1 - 8

- letter: L = Low, H = High, F = Falling Edge, R = Rising Edge

ST-Q, ST-Si, ST-C, ST-IP
SV7-S, SV7-Q, SV7-Si, SV7-C, SV7-IP

Parameter #1

Optional “X”, input number, input condition
NOTE: Including/omitting the optional “X” has no effect on the execution
of the command.

- units

integer, letter

- range

- integer: 0 (encoder index, if present), 1 - 8, 9 (Analog Command),
: (AIN1), ; (AIN2)

- letter: L = Low, H = High, F - Falling Edge, R = Rising Edge

Parameter #2

input number, input condition

- units

integer, letter

- range

- integer: 0 (encoder index, if present), 1 - 8, 9 (Analog Command),
: (AIN1), ; (AIN2)

- letter: L = Low, H = High, F = Falling Edge, R = Rising Edge