Er - encoder resolution, Command details, Parameter details – Applied Motion RS-232 User Manual

Page 73: Examples

Advertising
background image

73

920-0002 Rev. I

2/2013

Host Command Reference

ER - Encoder Resolution

Compatibility: Servo drives and stepper drives with encoder feedback
Affects:

Motor Operation

Sets the encoder resolution in quadrature counts. For example, if the motor connected to the drive has an 8000
count (2000 line) per revolution encoder, set the encoder resolution to 8000.

WARNING: Changing this setting will affect motor commutation with servo drives. Use the Quick Tuner
setup utility to change this setting, then run the “Timing Wizard” in Quick Tuner to properly set up the
motor commutation.

Command Details:

Structure

ER{Parameter #1}

Type

BUFFERED

Usage

READ/WRITE

Non-Volatile

YES

Register Access

None

Parameter Details:

Parameter #1

Encoder resolution

- units

encoder counts/rev

- range

200 - 128000

Examples:

Command

Drive sends

Notes

ER8000

-

Set encoder resolution to 8000 counts/rev

ER ER=8000

Advertising