AS - Analog Scaling

Compatibility: All stepper drives and SV servo drives
Affects:

Analog input

See also:

CM command

Sets or requests the analog input scaling setting. This is a code that determines what type of analog input scaling
is desired. The codes for selecting the various settings are in the Details table below.

Command Details:

Structure

AS{Parameter #1}

Type

BUFFERED

Usage

READ/WRITE

Non-Volatile

YES

Register Access

None

Parameter Details:

Parameter #1

Code

- units

integer number

- range

0 = single-ended +/- 10 volts
1 = single-ended 0 - 10 volts
2 = single-ended +/- 5 volts
3 = single-ended 0 - 5 volts
4 = differential +/- 10 volts
5 = differential 0 - 10 volts
6 = differential +/- 5 volts
7 = differential 0 - 5 volts

Examples:

Command

Drive sends

Notes

AS2

-

Analog input scaling set to single-ended +/- 5 volts

AS AS=2