Pp - power-up peak current, Command details, Parameter details – Applied Motion RS-232 User Manual

Page 158: Examples

Advertising
background image

158

920-0002 Rev. I
2/2013

Host Command Reference

PP - Power-up Peak current

Compatibility: Servo drives only
Affects:

Motor current, especially during acceleration and deceleration

See also:

CC, CP, PC commands

Sets or requests the power-up peak (RMS) current setting of the servo drive. This command differs from the CP
command in that in addition to setting the peak current of the drive, PP also immediately saves the setting to NV
memory. In other words, PP = CP + SA.

Command Details:

Structure

PP{Parameter #1}

Type

BUFFERED

Usage

READ/WRITE

Non-Volatile

YES

Register Access

None

Parameter Details:

Parameter #1

Power-up peak current limit

- units

amps RMS (resolution is 0.01 amps)

- range

BLuDC4: 0 - 13.5
BLuDC9: 0 - 18.0
BLuAC5: 0 - 15.0
SV7: 0 - 7.0
SVAC3 (120V): 0 - 7.5
SVAC3 (220V): 0 - 3.75

Examples:

Command

Drive sends

Notes

PP6

-

Set power-up peak current to 6.0 amps RMS

PP PP=6